關於(yu)電工(gong)絕緣套(tao)管(guan)及配件(jian)阻燃性(xing)能(neng)測(ce)定儀的試驗要求(qiu)
ZR-3050型(xing)觸摸屏電工(gong)套管(guan)阻燃性(xing)能(neng)測(ce)試儀/電(dian)工絕緣套(tao)管(guan)及配件(jian)阻燃性(xing)能(neng)測(ce)定儀
對(dui)於ZR-3050型(xing)電工套管阻燃性(xing)能(neng)測(ce)試儀用於(yu)電(dian)工阻燃套(tao)管(guan)及配件(jian)阻燃性(xing)能(neng)測(ce)定,符合(he)GB/T 13823.3、JG3050-1998≪建(jian)築用絕緣電(dian)工(gong)套管及配件(jian)≫標準(zhun)中6.10.1絕緣電(dian)工(gong)套管“自(zi)熄(xi)性試驗”中的要求(qiu)。儀器采(cai)用高(gao)壓(ya)點(dian)火器自(zi)動點(dian)火,造型(xing)講(jiang)究,耐(nai)煙氣腐(fu)蝕。關鍵(jian)元(yuan)器件(jian)采用(yong)進(jin)口件,數(shu)顯時(shi)間,試驗程序(xu)自動(dong)控(kong)制,使(shi)用方(fang)便(bian),穩(wen)定可靠(kao)。
ZR-3050型(xing)觸摸屏+PLC控制電工(gong)套(tao)管阻燃性(xing)能(neng)測(ce)試儀產品(pin)功(gong)能特點(dian)
1.可編程控(kong)制器觸(chu)摸屏(ping)+PLC控制,實現(xian)控(kong)制/檢測(ce)/計(ji)算/數(shu)據顯示多(duo)功(gong)能
2.自(zi)動化程(cheng)度高:自動記(ji)錄試驗時間,自(zi)動(dong)顯試結(jie)果(guo),自動(dong)計(ji)時,自(zi)動(dong)點(dian)火,施焰結(jie)束後(hou)本生(sheng)燈(deng)自動退(tui)回,可選(xuan)擇是否(fou)關(guan)閉燃氣(qi)
3.啟動時可選(xuan)擇是否(fou)自(zi)動(dong)點(dian)火
4.啟動、停止、燃氣(qi)、計(ji)時、點(dian)火、保存、保存、照明、排(pai)風(feng)均(jun)通過觸(chu)摸(mo)屏控制實現(xian),指(zhi)尖輕觸即(ji)可完(wan)成(cheng)試驗
5.計(ji)時按鈕(niu)配合(he)PLC自動(dong)記(ji)錄儲存(cun)燃燒(shao)耗時間
6.試驗時間系(xi)統自(zi)動(dong)記(ji)錄,並(bing)生(sheng)成(cheng)試驗結(jie)果(guo)
7. 設(she)備外(wai)形尺寸(cun):長60 cm 寬45cm 高156cm
8.燃氣(qi):液化石油氣(qi)代(dai)替(ti)(用(yong)戶自備);
9.火焰燃燒(shao)時間及火焰熄滅時(shi)間計(ji)時:0-999.9s±0.1s(計(ji)時精(jing)度(du) :0.1S),可連(lian)續(xu)設定,自動(dong)記(ji)錄,手(shou)動(dong)暫停;

10.本(ben)生(sheng)燈(deng)傾(qing)斜角(jiao)度(du):45°
11.式(shi)樣(yang)橫梁(liang)可前(qian)後(hou)移(yi)動(dong),根據式樣(yang)粗細(xi)調(tiao)節(jie)與(yu)本(ben)生(sheng)燈(deng)的位(wei)置;
12.燃燒(shao)噴燈(deng)標準功(gong)率(lv):1KW;噴嘴(本生(sheng)燈(deng))內徑(jing)9mm;
13.火焰:100mm,藍色錐(zhui)形焰心(xin):50mm;
14. 箱(xiang)體材(cai)料:鋼板靜電(dian)噴塗(tu)(支持全(quan)不(bu)銹鋼(gang)箱(xiang)體定做);
15.環(huan)境溫(wen)度(du)(標(biao)準(zhun)要求(qiu)):(23±2)℃ ;
16.電(dian)源電壓(ya):220V/50Hz 。
硬質套管施加火焰的時(shi)間
試驗材料(liao)厚A,mm | 施加火焰時間及操作 |
A≤2.5 | 間隔(ge)性(xing)施加火焰三(san)次(ci),每(mei)次(ci)施加火焰25s,間隔(ge)5s |
2.5≤A≤3.0 | 施加火焰壹次(ci),時(shi)間80s |
A>3.0 | 施加火焰壹次(ci),時(shi)間125s |
半(ban)硬質套管施加火焰的時(shi)間
試驗材料(liao)厚A | 壹(yi)次(ci)性(xing)施加火焰,施火時間,s | 試驗材料(liao)厚A mm | 壹(yi)次(ci)性(xing)施加火焰, 施火時間,s |
A≤0.5 | 15 | 3.5<A≤4.0 | 75 |
0.5<A≤1.0 | 20 | 4.0<A≤4.5 | 85 |
1.0<A≤1.5 | 25 | 4.5<A≤5.0 | 130 |
1.5<A≤2.0 | 35 | 5.0<A≤5.5 | 200 |
2.0<A≤2.5 | 45 | 5.5<A≤6.0 | 300 |
2.5<A≤3.0 | 55 | 6.0<A≤6.5 | 500 |
3.0<A≤3.5 | 65 |
|
|
設(she)計(ji)標準(zhun):JG3050-1998≪建(jian)築用絕緣電(dian)工(gong)套管及配件(jian)≫
試驗要求(qiu):取(qu)三(san)根600mm長套管為試樣(yang),將(jiang)試樣(yang)垂(chui)直(zhi)固定在燃燒(shao)裝置上(shang),將(jiang)調節(jie)好的本(ben)生(sheng)燈(deng)傾(qing)斜與水(shui)平成(cheng)45°,向(xiang)套管施加火焰時,應(ying)使(shi)本生(sheng)燈(deng)產生(sheng)的藍(lan)色(se)錐(zhui)形焰心(xin)的頂(ding)部與套管表(biao)面相接(jie)觸(chu),且(qie)此(ci)接(jie)觸點(dian)距套(tao)管底端的距(ju)離(li)為100mm。對(dui)於配(pei)件試驗受火處(chu)應(ying)為配件(jian)。完(wan)成(cheng)操(cao)作後(hou)移(yi)去(qu)火源。在試驗中如(ru)果(guo)試樣(yang)被(bei)點(dian)燃應(ying)無(wu)明顯(xian)的火焰傳(chuan)播搬(ban)去(qu)火源後(hou)套管或配件(jian)的火焰應(ying)在(zai)內熄(xi)滅(mie)。即(ji)自(zi)熄時間te≤30s。按JG3050-1998≪建(jian)築用絕緣電(dian)工(gong)套管及配件(jian)≫標準(zhun)5.2中的要求(qiu),電工(gong)套管(guan)阻燃性(xing)能(neng)試驗要求(qiu)的試驗除自(zi)熄時(shi)間外(wai)另有(you)氧指(zhi)數(shu)值。具(ju)體規(gui)定硬質套管自(zi)熄時間te≤30s且(qie)氧指(zhi)數(shu)OI≥32;半(ban)硬質、波紋管(guan)自(zi)熄時間te≤30s且(qie)氧指(zhi)數(shu)OI≥27;配件(jian)類自(zi)熄(xi)時(shi)間te≤30s且(qie)氧指(zhi)數(shu)OI≥32。
北(bei)京鑫(xin)生(sheng)卓銳科(ke)技有(you)限公(gong)司(si)