有的(de)客(ke)戶做(zuo)燃燒(shao)熱值測(ce)試的(de)時(shi)候(hou),有時候(hou)遇見(jian)氧(yang)彈點(dian)火(huo)失(shi)敗的(de)情(qing)況,燃燒(shao)熱值測(ce)試儀出(chu)現(xian)點(dian)火(huo)失(shi)敗情(qing)況怎(zen)麽辦(ban)?北京鑫(xin)生(sheng)卓銳科(ke)技(ji)有限公(gong)司技(ji)術服(fu)務部(bu)孫儷主任(ren)指(zhi)出(chu),如果只(zhi)出(chu)現(xian)壹(yi)次(ci),壹(yi)般(ban)為點(dian)火(huo)絲沒(mei)有裝好,若(ruo)多個樣(yang)品(pin)連續(xu)實(shi)驗點(dian)火(huo)失(shi)敗,可以先(xian)檢(jian)查(zha)點(dian)火(huo)絲有沒有燒(shao)斷,點(dian)火(huo)絲沒(mei)有燒(shao)斷,請(qing)檢查:

A、氧(yang)彈內部(bu)坩堝(guo)架(jia)是(shi)否(fou)短路;
B、點(dian)火(huo)電極(ji)與(yu)氧(yang)彈是(shi)否(fou)接觸(chu)良(liang)好,比(bi)如點(dian)火(huo)爪張得(de)太開、點(dian)火(huo)電極(ji)臟(zang);
C、可以(yi)用萬用表(biao)測量點(dian)火(huo)電極(ji)兩(liang)極(ji)間(jian),在點(dian)火(huo)時(可以手(shou)動(dong)在(zai)軟(ruan)件(jian)中(zhong)點(dian)“點(dian)火(huo)”)是(shi)否(fou)有點(dian)火(huo)電壓(ya)(熱值測(ce)試儀為交流24V左(zuo)右,),若(ruo)沒(mei)有壹(yi)般(ban)為點(dian)火(huo)電極(ji)連(lian)線松動(dong)或點(dian)火(huo)電路板(ban)壞(huai)。
d.查看(kan)氧(yang)氣氣壓(ya)是(shi)否(fou)高於5MP,如(ru)低(di)於5MP請(qing)給氧(yang)氣瓶(ping)中(zhong)加(jia)氣。

北(bei)京鑫(xin)生(sheng)卓銳科(ke)技(ji)有限公(gong)司技(ji)術服(fu)務部(bu)孫儷主任(ren)指(zhi)出(chu),燃燒(shao)熱值測(ce)試儀若(ruo)點(dian)火(huo)失(shi)敗,若點(dian)火(huo)絲已(yi)燒(shao)斷:
A、攪拌故障,如攪(jiao)拌桿卡(ka)死(si)、攪拌時轉時(shi)不轉等
B、內桶(tong)未(wei)進(jin)水(shui)或水(shui)量不(bu)夠(gou),可(ke)以通過實(shi)驗開始(shi)時(shi)觀(guan)察上(shang)水(shui)是(shi)否(fou)正常。
C、若(ruo)試樣(yang)已(yi)燃燒(shao)有可能(neng)是(shi)試樣(yang)熱(re)值過低(di),可(ke)以加(jia)添(tian)加(jia)物(wu)進(jin)行實(shi)驗。
D、若是(shi)做(zuo)苯甲酸實(shi)驗,點(dian)火(huo)絲熔進(jin)苯甲酸裏(li),點(dian)火(huo)絲接(jie)觸(chu)電阻(zu)太大(da)或苯甲(jia)酸原因。